PD4-C USB Online Manual

1010h Store Parameters

Function

Note
As an alternative, objects can also be set and saved using the configuration file. Note that this file has higher priority. Objects that are saved both with the mechanism described here as well as in the configuration file take the value of the configuration file.

This object has no function in this controller.

Object description


Index 1010h
Object name Store Parameters
Object Code ARRAY
Data type UNSIGNED32
Savable no
Firmware version FIR-v1426
Change history

Firmware version FIR-v1436: "Object name" entry changed from "Store Parameter" to "Store Parameters".

Firmware version FIR-v1436: The number of entries was changed from 3 to 4.

Firmware version FIR-v1512: The number of entries was changed from 4 to 5.

Firmware version FIR-v1540: The number of entries was changed from 5 to 7.


Value description


Subindex 00h
Name Highest Sub-index Supported
Data type UNSIGNED8
Access read only
PDO mapping no
Allowed values  
Preset value 06h


Subindex 01h
Name Save All Parameters To Non-volatile Memory
Data type UNSIGNED32
Access read / write
PDO mapping no
Allowed values  
Preset value 00000001h


Subindex 02h
Name Save Communication Parameters To Non-volatile Memory
Data type UNSIGNED32
Access read / write
PDO mapping no
Allowed values  
Preset value 00000001h


Subindex 03h
Name Save Application Parameters To Non-volatile Memory
Data type UNSIGNED32
Access read / write
PDO mapping no
Allowed values  
Preset value 00000001h


Subindex 04h
Name Save Customer Parameters To Non-volatile Memory
Data type UNSIGNED32
Access read / write
PDO mapping no
Allowed values  
Preset value 00000001h


Subindex 05h
Name Save Drive Parameters To Non-volatile Memory
Data type UNSIGNED32
Access read / write
PDO mapping no
Allowed values  
Preset value 00000001h


Subindex 06h
Name Save Tuning Parameters To Non-volatile Memory
Data type UNSIGNED32
Access read / write
PDO mapping no
Allowed values  
Preset value 00000001h

▶   weiter