3322h Analogue Input Pre-scaling

Function

Value by which the read analog value (3320h, 3321h) is divided before it is written in object 3320h.

Object description


Index 3322h
Object name Analogue Input Pre-scaling
Object Code ARRAY
Data type INTEGER32
Savable yes, category: application
Firmware version FIR-v1426
Change history  

Value description


Subindex 00h
Name Number Of Analogue Inputs
Data type UNSIGNED8
Access read only
PDO mapping no
Allowed values  
Preset value 02h


Subindex 01h
Name Analogue Input 1
Data type INTEGER32
Access read / write
PDO mapping no
Allowed values All values permitted except 0
Preset value 00000001h


Subindex 02h
Name Analogue Input 2
Data type INTEGER32
Access read / write
PDO mapping no
Allowed values All values permitted except 0
Preset value 00000001h

Description

The subindices contain:

  • Subindex 00h: Number of divisors
  • Subindex 01h: Divisor for analog input 1
  • Subindex 02h: Divisor for analog input 2
▶   weiter

Inhalt







Einstellungen zum Datenschutz
Wir verwenden essenzielle Cookies, die für den Betrieb unserer Website erforderlich sind. Mit Ihrer Einwilligung verwenden wir zudem optionale Cookies für Statistik und Marketing. Sie können den nicht-essenziellen Cookies per Klick auf die Schaltfläche „Akzeptieren“ zustimmen oder diese ablehnen. Ihre Einstellungen können Sie jederzeit aufrufen und ihre Zustimmung auch nachträglich widerrufen. Nähere Hinweise hierzu erhalten Sie in unserer Datenschutzerklärung.