N5 EtherCAT Online Manual

3321h Analogue Input Offset

Function

Offset that is added to the read analog value (3320h) before dividing by the divisor from object 3322h.

Object description

Index 3321h
Object name Analogue Input Offset
Object Code ARRAY
Data type INTEGER32
Savable yes, category: application
Firmware version FIR-v1426
Change history

Value description

Subindex 00h
Name Number Of Analogue Inputs
Data type UNSIGNED8
Access read only
PDO mapping no
Allowed values
Preset value 02h
Subindex 01h
Name Analogue Input 1
Data type INTEGER32
Access read / write
PDO mapping no
Allowed values
Preset value 00000000h
Subindex 02h
Name Analogue Input 2
Data type INTEGER32
Access read / write
PDO mapping no
Allowed values
Preset value 00000000h

Description

  • Subindex 00h: Number of offsets
  • Subindex 01h: Offset for analog input 1
  • Subindex 02h: Offset for analog input 2
▶   weiter

Inhalt



Einstellungen zum Datenschutz
Wir verwenden essenzielle Cookies, die für den Betrieb unserer Website erforderlich sind. Mit Ihrer Einwilligung verwenden wir zudem optionale Cookies für Statistik und Marketing. Sie können den nicht-essenziellen Cookies per Klick auf die Schaltfläche „Akzeptieren“ zustimmen oder diese ablehnen. Ihre Einstellungen können Sie jederzeit aufrufen und ihre Zustimmung auch nachträglich widerrufen. Nähere Hinweise hierzu erhalten Sie in unserer Datenschutzerklärung.