N5 EtherCAT Online Manual

3252h Digital Output Routing

Function

This object assigns a signal source to an output; this signal source can be controlled with 60FEh.

Object description

Index 3252h
Object name Digital Output Routing
Object Code ARRAY
Data type UNSIGNED16
Savable yes, category: application
Access read only
PDO mapping no
Allowed values
Preset value
Firmware version FIR-v1650-B527540
Change history

Value description

Subindex 00h
Name Highest Sub-index Supported
Data type UNSIGNED8
Access read only
PDO mapping no
Allowed values
Preset value 05h
Subindex 01h
Name Output Control #1
Data type UNSIGNED16
Access read / write
PDO mapping TX-PDO
Allowed values
Preset value 1080h
Subindex 02h
Name Output Control #2
Data type UNSIGNED16
Access read / write
PDO mapping TX-PDO
Allowed values
Preset value 0090h
Subindex 03h
Name Output Control #3
Data type UNSIGNED16
Access read / write
PDO mapping TX-PDO
Allowed values
Preset value 0091h
Subindex 04h
Name Output Control #4
Data type UNSIGNED16
Access read / write
PDO mapping TX-PDO
Allowed values
Preset value 0092h
Subindex 05h
Name Output Control #5
Data type UNSIGNED16
Access read / write
PDO mapping TX-PDO
Allowed values
Preset value 0093h
▶   weiter

Inhalt



Einstellungen zum Datenschutz
Wir verwenden essenzielle Cookies, die für den Betrieb unserer Website erforderlich sind. Mit Ihrer Einwilligung verwenden wir zudem optionale Cookies für Statistik und Marketing. Sie können den nicht-essenziellen Cookies per Klick auf die Schaltfläche „Akzeptieren“ zustimmen oder diese ablehnen. Ihre Einstellungen können Sie jederzeit aufrufen und ihre Zustimmung auch nachträglich widerrufen. Nähere Hinweise hierzu erhalten Sie in unserer Datenschutzerklärung.