N5 EtherCAT Online Manual

3220h Analog Inputs

Function

Displays the instantaneous values of the analog inputs in digits.

With object 3221h, the respective analog input can be configured as current or voltage input.

Object description

Index 3220h
Object name Analog Inputs
Object Code ARRAY
Data type INTEGER16
Savable no
Firmware version FIR-v1426
Change history

Value description

Subindex 00h
Name Highest Sub-index Supported
Data type UNSIGNED8
Access read only
PDO mapping no
Allowed values
Preset value 02h
Subindex 01h
Name Analogue Input 1
Data type INTEGER16
Access read only
PDO mapping TX-PDO
Allowed values
Preset value 0000h
Subindex 02h
Name Analogue Input 2
Data type INTEGER16
Access read only
PDO mapping TX-PDO
Allowed values
Preset value 0000h

Description

Formulas for converting from [digits] to the respective unit:
  • Voltage input: (x digits – 512 digits) * 20 V / 1024 digits
  • Current input: x digits * 20 mA / 1024 digits
▶   weiter

Inhalt



Einstellungen zum Datenschutz
Wir verwenden essenzielle Cookies, die für den Betrieb unserer Website erforderlich sind. Mit Ihrer Einwilligung verwenden wir zudem optionale Cookies für Statistik und Marketing. Sie können den nicht-essenziellen Cookies per Klick auf die Schaltfläche „Akzeptieren“ zustimmen oder diese ablehnen. Ihre Einstellungen können Sie jederzeit aufrufen und ihre Zustimmung auch nachträglich widerrufen. Nähere Hinweise hierzu erhalten Sie in unserer Datenschutzerklärung.